The Method of Install or Remove SFP Transceiver Modules on Cisco Device

The SFP (small form-factor pluggables) transceiver modules are hot-pluggable I/O devices that plug into module sockets. The transceiver connects the electrical circuitry of the module with the optical or copper network. SFP transceiver modules are the key components in today's transmission network. Thus, it is necessary to master the skill of installing or removing a transceiver modules to avoid unnecessary loss. This tutorial are going to guide you how to install or remove SFP transceiver module in a right way.


Things Should Be Know Before Installing or Removing SFP

Before removing or installing a Transceiver Module you must disconnect all cables, because of leaving these attached will damage the cables, connectors, and the optical interfaces. At the same time please be aware that do not often remove and install an SFP transceiver and it can shorten its useful life. For this reason transceivers should not be removed or inserted more often than is required. Furthermore, transceiver modules are sensitive to static, so always ensure that you use an ESD wrist strap or comparable grounding device during both installation and removal.

Required Tools

You will need these tools to install the SFP transceiver module:
1.Wrist strap or other personal grounding device to prevent ESD occurrences.
2.Antistatic mat or antistatic foam to set the transceiver on.
3.Fiber-optic end-face cleaning tools and inspection equipment
Installing SFP Transceiver Modules


SFP transceiver modules can have three types of latching devices to secure an SFP transceiver in a port socket:

1.SFP transceiver with a Mylar tab latch.
2.SFP transceiver with an actuator button latch.
3.SFP transceiver that has a bale-clasp latch.

Types of SFP Latching

Determine which type of latch your SFP transceiver uses before following the installation and removal procedures.


To install an SFP transceiver, follow these steps:
Step 1. Attach an ESD-preventive wrist strap to your wrist and to the ESD ground connector or a bare metal surface on your chassis.
Step 2. Remove the SFP Transceiver Module from its protective packaging.
Note: Do not remove the optical bore dust plugs until directed to do so later in the procedure.
Step 3. Check the label on the SFP transceiver body to verify that you have the correct model for your network.
Step 4. Find the send (TX) and receive (RX) markings that identify the top side of the SFP transceiver.
Note: On some SFP transceivers, the TX and RX marking might be replaced by arrowheads that point from the SFP transceiver connector (transmit direction or TX) and toward the connector (receive direction or RX).
Step 5. Position the SFP transceiver in front of the socket opening.
Note: Different Cisco devices have different SFP module socket configurations. Your Cisco device could have either a latch-up or a latch-down orientation. Ensure that you are installing the SFP transceiver in the correct orientation for your Cisco device. Refer to the hardware installation instructions that came with your Cisco device for more details.
Step 6. Insert the SFP transceiver into the socket until you feel the SFP Transceiver Module connector snap into place in the socket connector.
Note: For optical SFP transceivers, before you remove the dust plugs and make any optical connections, observe these guidelines:
a. Always keep the protective dust plugs on the unplugged fiber-optic cable connectors and the transceiver optical bores until you are ready to make a connection.
b. Always inspect and clean the LC connector end-faces just before you make any connections. See the Required Tools section of this document for more information.
c. Always grasp the LC connector housing to plug or unplug a fiber-optic cable.

Step 7. Remove the dust plugs from the network interface cable LC connectors. Save the dust plugs for future use.
Step 8. Inspect and clean the LC connector’s fiber-optic end-faces.
Step 9. Remove the dust plugs from the SFP transceiver optical bores.
Step 10. Immediately attach the network interface cable LC connector to the SFP transceiver.
Step 11. Connect the 1000BASE-T SFP transceivers to a copper network.

Caution: In order to comply with GR-1089 intrabuilding lightning immunity requirements, you must use grounded, shielded, twisted-pair Category 5 cabling.

Complete these steps in order to connect the transceivers to a copper network:
a.Insert the Category 5 network cable RJ-45 connector into the SFP transceiver RJ-45 connector.
Note: When you connect to a 1000BASE-T-compatible server, workstation, or router, use four twisted-pair, straight-through Category 5 cabling for the SFP transceiver port. When you connect to a 1000BASE-T-compatible switch or repeater, use four twisted-pair, crossover Category 5 cabling.
b.Insert the other end of the network cable into an RJ-45 connector on a 1000BASE-T-compatible target device.
c. Reconfigure and reboot the target device if necessary.

Step 12. Observe the port status LED:
a. The LED turns green when the SFP transceiver and the target device have an established link.
b. The LED turns amber while STP discovers the network topology and searches for loops. This process takes about 30 seconds, and then the LED turns green.
c. If the LED is off, the target device might not be turned on, there might be a cable problem, or there might be a problem with the adapter installed in the target device. Refer to the Troubleshooting section of your switch hardware guide for solutions to cabling problems.


Removing SFP Transceiver Modules
Step 1. Attach an ESD-preventive wrist strap to your wrist and to the ESD ground connector or a bare metal surface on your chassis.
Step 2. Disconnect the network fiber-optic cable or network copper cable from the SFP Transceiver Module connector. For optical SFP transceivers, immediately reinstall the dust plugs in the SFP transceiver optical bores and the fiber-optic cable LC connectors.
Tips: For reattachment of fiber-optic cables, note which connector plug is send (TX) and which is receive (RX).
Step 3. Release and remove the SFP Transceiver Module from the socket connector.
a. If the SFP transceiver has a Mylar tab latch, pull the tab gently in a slightly downward direction until the transceiver disengages from the socket connector, and then pull the SFP transceiver straight out. Do not twist or pull the Mylar tab because you could detach it from the SFP transceiver.

Removing-SFP-with-Mylar-Tab
b. If the SFP transceiver has an Actuator button latch, gently press the actuator button on the front of the SFP transceiver until it clicks and the latch mechanism releases the SFP transceiver from the socket connector. Grasp the actuator button between your thumb and index finger, and carefully pull the SFP transceiver straight from the module slot.
Removing-SFP-with-Actuator-Button-Latch
c. If the SFP transceiver has a Bale-clasp latch, pull the bale out and down to eject the SFP transceiver from the socket connector. If the bale-clasp latch is obstructed and you cannot use your index finger to open it, use a small flat-blade screwdriver or another long narrow instrument to open the bale-clasp latch. Grasp the SFP transceiver between your thumb and index finger, and carefully remove it from the socket.

Removing -SFP-with-a-Bale-Clasp-Latch
Step 4. Place the removed SFP transceiver in an antistatic bag or other protective environment.

2016-12-26

Fundamentals of DWDM Optical Passive Components Technology

The emergence of DWDM is one of the most recent and important phenomena in the development of fiber optic transmission technology. This tutorial will introduce the fundamentals of DWDM technology, such as the components, optical amplifiers used in DWDM system, etc.


Components and Operation
DWDM is a core technology in an optical transport network. The essential components of DWDM can be classified by their place in the system. On the transmit side, there are lasers with precise, and stable wavelengths. On the link, there is optical fiber that exhibits low loss and transmission performance in the relevant wavelength spectra, in addition to flat-gain optical amplifiers to boost the signal on longer spans. On the receive side, there are photodetectors and demultiplexers using thin film filters or diffractive elements. Besides these components, optical add/drop multiplexers and optical cross-connect components may be used.

The main job of optical fibers is to guide lightwaves with a minimum of attenuation (loss of signal). Multimode fiber and single-mode fiber are the general two categories of optical fiber in use today. Single-mode fiber has a much smaller core that allows only one mode of light at a time through the core. As a result, the fidelity of the signal is better retained over longer distances, and modal dispersion is greatly reduced. These factors attribute to a higher bandwidth capacity than multimode fibers are capable of. For its large information-carrying capacity and low intrinsic loss, single-mode fibers are preferred for longer distance and higher bandwidth applications, including DWDM.

Erbium Doped Fiber Amplifier (EDFA)

By making it possible to carry the large loads that DWDM is capable of transmitting over long distances, the EDFA was a key enabling technology. Erbium is a rare-earth element that, when excited, emits light around 1.54 micrometers—the low-loss wavelength for optical fibers used in DWDM. The picture below shows a simplified diagram of an EDFA. A weak signal enters the erbium-doped fiber, into which light at 980 nm or 1480 nm is injected using a pump laser. This injected light stimulates the erbium atoms to release their stored energy as additional 1550-nm light. As this process continues down the fiber, the signal grows stronger.

Multiplexers and Demultiplexers
As DWDM systems send signals from several sources over a single fiber, they must include some means to combine the incoming signals. This is done with a multiplexer, which takes optical wavelengths from multiple fibers and converges them into one beam. At the receiving end, the system must be able to separate out the components of the light so that they can be discreetly detected. Demultiplexers perform this function by separating the received beam into its wavelength components and coupling them to individual fibers. Demultiplexing must be done before the light is detected, because photodetectors are inherently broadband devices that cannot selectively detect a single wavelength.

In a unidirectional system, there is a multiplexer at the sending end and a demultiplexer at the receiving end shown in the following picture. Two system would be required at each end for bidirectional communication, and two separate fibers would be needed.

unidirectional system
In a bidirectional system, there is a multiplexer/demultiplexer at each end and communication is over a single fiber pair.

bidirectional system
Multiplexers and demultiplexers can be either passive or active in design. Passive designs are based on prisms, diffraction gratings, or filters, while active designs combine passive devices with tunable filters.


Optical Add/Drop Multiplexers (OADM)
Between multiplexing and demultiplexing points in a DWDM system, there is an area in which multiple wavelengths exist. It is often desirable to be able to remove or insert one or more wavelengths at some point along this span. An optical add/drop multiplexer performs this function. Rather than combining or separating all wavelengths, the OADM can remove some while passing others on. OADM is a key part of moving toward the goal of all-optical networks.

There are two general types of OADMs. The first generation is a fixed device that is physically configured to drop specific predetermined wavelengths while adding others. The second generation is reconfigurable and capable of dynamically selecting which wavelengths are added and dropped.

Operation of a Transponder Based DWDM System

Within the DWDM system, a transponder converts the client optical signal. The following picture shows the end-to-end operation of a unidirectional DWDM system.
anatomy of dwdm system

The following steps describe the system shown in the picture above.
1. The transponder accepts input in the form of standard single-mode or multimode laser. The input can come from different physical media and different protocols and traffic types.
2. The wavelength of each input signal is mapped to a DWDM wavelength.
3. DWDM wavelengths from the transponder are multiplexed into a single optical signal and launched into the fiber. The system might also include the ability to accept direct optical signals to the multiplexer; such signals could come, for example, from a satellite node.
4. A post-amplifier boosts the strength of the optical signal as it leaves the system (optional).
5. Optical amplifiers are used along the fiber span as needed (optional).
6. A pre-amplifier boosts the signal before it enters the end system (optional).
7. The incoming signal is demultiplexed into individual DWDM lambdas (or wavelengths).
8. The individual DWDM lambdas are mapped to the required output type (for example, OC-48 single-mode fiber) and sent out through the transponder.

FAQ about Video SFP Transceivers

1. What is SDI?
SDI, the abbreviation for Serial Digital Interface, is a digital video interface standard made by SMPTE organization. This serial interface transmits every bit of data word and corresponding data through single channel. Due to the high data rate of serial digital signal(a kind of digital baseband signal), it must be processed before transmission.

2. What are the categories of video transceiver modules?
It can be divided traditionally by operating rate into HD-SDI, 3G-SDI, 6G-SDI, 12G-SDI; by transmission mode into single Tx, single Rx, dual Tx, dual Rx and TR transceivers; by standards into MSA and non-MSA; by operating wavelength into 1310nm, 1490nm, 1550nm and CWDM wave length. It also exists video modules of electrical interfaces that adapting mini BNC port to coordinate with SFP slot-supporting digital matrix. Currently there are also on the market some crossover video transceivers, for example, transfer the encoded SG-SDI to IP protocol conversion module can be used in traditional Ethernet switch, replacing video codec equipment.


3. What are the data rate of digital SDI?



4. What is 3G-SDI Pathological Patterns? 
SDI Proving Ground(also called Pathological Patterns) is a whole test signal, thus it must be done during blackout. SDI proving ground signal is difficult to handle by serial digital system, and significant to check the system performance. Regularly SDI Proving Ground contains the richest low-frequency energy which statistically happens one per frame. One component of SDI proving ground is, 19 zeros in a sequence, followed by a one (or 19 ones followed by a zero), can be used to test the working condition of equalizer. This sequence produces vast DC component to strengthen the analog ability of equipment and transmission system processing signal. The test signal appears with purple background on the top of the image display. The another component of SDI Proving Ground signal is used to check the phase lock loop performance. It is an unusual signal sequence, consists of 20 zeros followed by 20 ones. It has minimum zero crossing point used for clock extraction. This signal appears with Grey background on the bottom of the image display. Pathological Patterns test is also an important indicator of video SFP modules.

5. What are 6G-SDI and 12G-SDI applied in?
Generally in HD digital broadcasting field, such as digital output port of TV station HD professional camera. One-channel 6G-SDI can transmit 36fps 4K resolution zero-compressed video, while one-channel 12G-SDI can transmit 60fps 4K resolution zero-compressed video.

6. What are the main differences between HDMI and SDI?
a. Different transmit mode: Adapting parallel mode, HDMI cables contain up to 19 pairs of wires; while SDI adapts serial mode and contains only one pair of wire.
b. HDMI is applied for consumer products, like DVO from consumer camera, game machine and HD digital Set Top Box; when SDI applied in broadcast market, like TV stations and studio.
c. HDMI interface supports HDCP encryption HD digital copyright protection, but not SDI.

7. What is SDI digital video matrix? What main functions it has?
Digital video matrix arbitrarily exports m channel video signal to the electronic device on n channelmonitor equipment by switching array method, realizes video switch function through digital Cross-point chip, which realized by artificially plugging the copper shaft joint of distribution frame before the digital video matrix appearance. Presently digital matrix has been distinguished by working bandwidth, such as the type supporting 3G-SDI high-speed signal; usually each input-output port supports automatic equilibrium function; and high-end model has CDR clock regeneration function, on port types it has BNC copper shaft joint, also video SFP supportable fiber interface. With module design, it is more flexible to deploy and convenient to use.

8. What long-distance transmission solutions applying 3G-SDI, 6G-SDI and 12G-SDI?
3G-SDI, 6G-SDI and 12G-SDI both are digital baseband signal, thus limited with long-distance transmission on copper cable, for instance, 3G-SDI signal can transmit up to 55 meters on premium copper cables, but that will be much decreased to within 10 meters as for 6G-SDI and 12G-SDI, what’s more, copper cable transmission is susceptible to outside electromagnetic interference. If high-speed baseband signal proceeds optics and electrics conversion, then it can be greatly solved through optic-fiber cables. Currently the generic 3G-SDI video transceivers in marketplace is with transmission distance up to 40km on singlemode optical cables, and it will be easily to solve long-distance transport with 3G-SDI transmitter. Meanwhile there are many optical module options supporting CWDM waveband, which save much fiber resource by carrying WDM(wavelength division multiplexing) on single fiber. Now 6G-SDI and 12G-SDI optical transceivers gradually are commercially available.

9. What’s the difference between MSA and Non-MSA standards of 3G-Video SFP optical transceiver modules? What will be the consequence if they match wrongly to host machine?
The gold finger of 3G-Video SFP transceivers have 20 pins, MSA ans Non-MSA differ in I2C pin definition: MSA standard defines I2C definition on the fourth pin (SDA) and the fifth pin (SCL); while Non-MSA standard defines it on the fifth and sixths pins.

I2C pins failing to match the host machine can directly lead to SFP module communication connecting error to host machine I2C, it comes out the SFP DDM function is unavailable and EEPROM unreadable by host machine.

25GbE VS 40GbE Cabling


In 2015 data center optics market, the 40GbE transceivers is ubiquitous and the market of 40GbE is encouraging. However, with 100GbE rapidly becoming the new standard in transport, the rules of game seems to have changed. A new voice is announcing: 25GbE is more preferred and the death of 40GbE was never in doubt. Why? This tutorial will make a comparison of 25GbE and 40GbE cabling.

40GbE Cabling Overview
40 GbE, namely 40 Gigabit Ethernet, is a standard developed by the IEEE 802.3ba Task Force to support sending Ethernet frames at 40 Gbps (Gigabits per second). The official development of 40GbE standards began most early in January 2008, and the standards were officially approved in June 2010.
IEEE 802.3 Standard Interfaces that Specify 40GbE
At the heart of the 40GbE network layer is a pair of transceivers connected by a cable—OM4 or OM3 fiber cable. The transceivers, in turn, are plugged into either network servers or a variety of components, including interface cards and switches.

40GbE Optics & Cables
There are several standard form factors of 40GbE transceivers in the whole evolution. The CFP (C Form-Factor Pluggable) transceiver uses 12 Tx and 12 Rx 10Gbps lanes to support one 100GbE port, or up to three 40GbE ports. With its larger size, it can meet the needs of single-mode optics and can easily serve multimode optics or copper. But it is gradually falling behind since the increasing demands for high density. Another form factor is the CXP. It also provides twelve 10Gbps lanes in each direction, but is much smaller than the CFP and serves the needs of multimode optics and copper. At present, the most commonly used 40GbE form factor is the Quad Small Form-Factor Pluggable since it is similar in size to the CXP but can provide four Tx and four Rx lanes to support 40GbE applications for single-mode, multimode fiber and copper.
Fiber optic cabling or copper cabling are both available for 40 GbE. The supportable channel length depends on the cable and the transceiver type. For data center 40GbE fiber optic cabling, OM3 and OM4 multimode cabling is generally recommended because its reach supports a wider range of deployment configurations compared to copper solutions. In addition, compared to single-mode solutions, it costs lower. For connector type, it is no longer the duplex LC in this case. In the 802.3ba standard, MPO/MTP connectors are used at the multimode transceivers to support the multifiber parallel optics channels.



25GbE Cabling Overview
25GbE is a standard developed by IEEE 802.3 Task Force P802.3by in July 2014, using for Ethernet servers and switches connectivity in a datacenter environment. The upcoming IEEE 802.3by 25GbE standard is technically complete and expected to be ratified by June of 2016. Meanwhile, the industry expects that 25GbE hardware will be available as early as 2015 with the standard finalized by 2016.
IEEE 802.3 Standard Interfaces that Specify 25GbE.

25GbE Optics & Cables
The 25GbE physical interface specification supports two main form factors—SFP28 (1x25 Gbps) and QSFP28 (4x25 Gbps).
The 25GBASE-SR SFP28 is an 850nm VCSEL 25GbE transceiver available in the market. It is designed to transmit and receive optical data over 50/125┬Ám multimode optical fiber (MMF) and support up to 70m on OM3 MMF and 100m on OM4 MMF (LC duplex). In fact, using an SFP28 direct attach copper (DAC) cable for switches direct connection is more commonly used now. In addition, a more cost-effective solution is recommended that is to use a QSFP28 to connect a 100GbE QSFP28 switch port to four SFP28 ports. DAC cable lengths are limited to three meters for 25GbE. Thus, the active optic cable (AOC) solutions are also used for longer lengths of application.
25GbE Cabling vs 40G Cabling
Compared to 40 GbE, the 25GbE seems to be more suitable and cost-effective for cloud and web-scale data center applications. Using 25GbE with QSFP28 transceivers, users can deliver a single-lane connection that is similar to existing 10GbE technology, but with 2.5X faster performance. In addition, 25 GbE can provide superior switch port density by requiring just one lane (vs. 4 x lanes with 40 GbE). Thus, it costs less and requires lower power consumption.

Benefits of 25 GbE when compared to 40 GbE are shown as below:
Maximum switch I/O performance and fabric capability
2.5 times the performance of 10 GbE
Greater port density vs 40 GbE (one lane vs. four lanes)
Reduced capital expenditures (CAPEX)
Fewer ToR switches and fewer cables
Lower cost versus 40 GbE
Reduced operational expenditures (OPEX)
Requires less power, cooling, and footprint
Leverage of existing IEEE 100GbE standard


Summary
No matter the market research or the attitude of users, 25 GbE seems to be the preferred option in the next step. Actually, coming back to reality, there will be a significant increase in 100GbE and 25GbE port density this year. However, will 40 GbE be replaced and dead? We do not know what will happen in the future. But the trends will always be higher speed, wider band, and higher port density. 25 GbE vs 40 GbE, let's wait and see how things play out.

2016-12-05

What differences does 100G QSFP28 brings?


100G networks will be the most popular type in the next 10 years even now 10G networks is still the most popular one. But a lot of network builders are choosing 100G to replace it. But how to replace it and which is the most economic way? They need think about this.

As we all know, 100G products is very expensive. Considering the cost, a lot of network builders choose 10G→40G→100G before QSFP28 come out. At that time there are 100G products such CFP, CFP2 and CFP4 ("C" for 100, and FP for "Form factor, Pluggable”). But the form fact of all these are huge even the newest CFP4 is still bigger than QSFP28. Please refer to the picture below:


After 100GBASE QSFP28 has been released, it provides a more economic way. We can choose 10G→25G→100G, because 100G Ethernet is formed by 4*25Gbps. QSFP28 form factor make it possible to install more transceivers in one 1RU switch.

With respect to 40GE, 25GE enjoys the cost advantages of single channel. If it is 40G, multiple physical channels are required, because it makes use of 10G technology. For 25G Ethernet, the key advantage is that many components have been completed: because 100G Ethernet is formed by 4 25Gbps. Therefore, the components generated using the two kinds of technology can be produced in mass, to drive down the price.

Besides, the consumption of QSFP28 is below 3.5W which is much lower than other 100G products (6~24W). The GEN2 100G QSFP28 released by Infiberone only cost 2.5W.

2016-11-27

Infiberone Starts Batch Production of 40G QSFP GEN2 Optical Transceiver


Infiberone announced last Friday it’s gone into the batch production of their newly released 40G QSFP GEN2 optical transceiver. The main difference between 40G QSFP GEN2 and existing 40G QSFP on the market lies in the multichannel real-time DDM function, which is easy to realize for transceivers with data rate lower than 10Gbps, but very complicated for those more than 10Gbps, as the latter is mostly based on COB not TO packaging technique. As for parallel high-speed optical transceiver with higher rate, it requires excellent design and precise layout to realize optic circuit detection on 4-channel or 12-channel array light chip in an extremely limited space, which has been met by Infiberone patented optical engine technology. Starting optical engine technology development since 2011, now by its own endeavor and cooperation with quality suppliers, Infiberone has gained rich experience and unique technology about array LENS development and integrated optical devices coupling capsulation. It is a critical mission for Infiberone R&D long-term works that realizing multichannel optical power DDM real-time monitoring of high-speed parallel optical module. Lack of optical power real-time monitoring does not influence optical modules regular operation; however Infiberone‘s been striving to create product higher than industry standard and holds firm pursuit of optical module complete functions, and finally they reach this goal.

It says that Infiberone new launched GEN2 optical module will not largely increase clients’ purchasing cost. The bulk price of GEN1 and GEN2 almost reach equilibrium, even GEN2 module is a truly flawless product compliant with related standards. Infiberone launched this new product at CIOE in September 2015, and now plans to completely switch the generation products in the first half of 2016.

By the way, Infiberone is going to attend OFC exhibition in USA this month, let's meet there to communicate about new products.

2016-11-25

How to Install or Remove SFP Transceiver Modules on Cisco Device


The SFP (small form-factor pluggables) transceiver modules are hot-pluggable I/O devices that plug into module sockets. The transceiver connects the electrical circuitry of the module with the optical or copper network. SFP transceiver modules are the key components in today's transmission network. Thus, it is necessary to master the skill of installing or removing a transceiver modules to avoid unnecessary loss. This tutorial are going to guide you how to install or remove SFP transceiver module in a right way.

Things Should Be Know Before Installing or Removing SFP
Before removing or installing a Transceiver Module you must disconnect all cables, because of leaving these attached will damage the cables, connectors, and the optical interfaces. At the same time please be aware that do not often remove and install an SFP transceiver and it can shorten its useful life. For this reason transceivers should not be removed or inserted more often than is required. Furthermore, transceiver modules are sensitive to static, so always ensure that you use an ESD wrist strap or comparable grounding device during both installation and removal.

Required Tools
You will need these tools to install the SFP transceiver module:
1.Wrist strap or other personal grounding device to prevent ESD occurrences.
2.Antistatic mat or antistatic foam to set the transceiver on.
3.Fiber-optic end-face cleaning tools and inspection equipment

The main technical trends of optical communication


In the field of optical communication, different companies hold different opinions about the trends of this industry. But we would like to talk about our ideas today to share with you all.
The main trends of current optical products including:
A miniaturization and integration;
B miniaturization and lower cost;
C higher speed and larger capacity;
D lower power consumption;
E closed proprietary to open and flexible.

Smaller, more integrated, lower cost, lower power consumption, greater capacity, in fact, is the development trend of optical communication products. And the last one(E) to open and flexible,  is the new trend of SDN technology, but also the most important trend.

Miniaturization, integration, low cost, high speed, large capacity and low power consumption, all these have been the requirements of optical communication products in different times. But they present different details in different times even they always combine each together. In 2016, the ultra small PD of German Karlsruhe Institute, TE micro QSFP, QSFP DD and other MSA are on behalf of the development of this miniaturization technology. In the aspect of the integration technology, silicon photonic is very hot this year, but not the only option. In fact, integration is not only the integration of the chip level, the current integration of active devices and passive devices is also a kind of integration. There are very few individual passive or active devices.

Optical communications manufacturers have been committed to reducing costs and power consumption. The emergence of the ACO CFP module is a cost reduction effort. COBO alliance’s goal is to reduce cost, but also to reduce power consumption. The emergence of the technology is directly related to the needs of the system vendors. Ignoring the impact of these trends, today's dominant manufacturers may fall behind. These technological changes are more important for China's optical communications companies, because these technologies may be more likely to change the package. After all, to make progress like Ranovus in the quantum dot chip is not easy for Chinese manufacturers.

High speed and large capacity is always the goal of optical communication companies. Current hot spots in this area are related to modulation techniques and optical fibers in the 400Gbps and more high speed systems. Compared to the pursuit on the 400Gbps and the experiment, China's optical communication companies should pay more attention to the 25Gbps system. Regardless of Ethernet, PON or 5G mobile communications, 25Gbps will become an important rate in the near future.

From the closed proprietary OEM network equipment to steering flexible reconfigurable open platform is the most important trend in optical communication technology this year since OFC. TIP of Facebook shows ADVA and other equipment companies will support open source optical network equipment plan. From closed to open is the trend of the Internet era, and optical communication will not be forever excluded. How to make our products more flexible and how to support open source, these should be the important issues in the next two years of us all.

2016-11-17

High Density MPO/MTP Cabling System


Typical Application Scenario—Data Center SAN
In today’s fast-moving cyber world, with the advent and popularity of cloud computing and big data, the demand for high-speed transmission and data capacity is becoming much greater than ever before. There exist millions of servers in some cloud-computing data centers of big IT giant companies like Google, Facebook, Tencent, thus, how to balance high capacity & high transmission data rate and low power consumption is a major challenge facing today’s data center. In the mean time, the prevalence of smart phone, i-pad and other intelligent equipments leads to the data explosion than expected, which all has a more demanding request for higher network capacity.

As the data throughput increases, 40Gb/s and 100Gb/s are more commonplace and now become a trend and hotspot for data-center cabling system, plus the fact that MPO/MTP connector is the up-and-coming standard optical interface for 40G and 100G Ethernet network, so it is predicted that MPO/MTP will eventually replace the standards for fiber optics as known. Even now many big IT companies are tearing out their existing infrastructure and placing MPO/MTP cassettes in their patch panels to route data for thousands of network electronics, they find MPO/MTP cassettes, patch-cords, connectors and adapters an essential backbone to their infrastructure. If you run one 12-fiber MPO/MTP cable from a cassette on one side of the building to one cassette on the other, you can supply data for 12 connections just like that. The high fiber count in one connector creates endless possibilities. Imagining a 1U rack mount patch panel that can supply data to run an entire 288-port switch, it will happen soon with today's increasing demand for higher through-put, so the needs for. FC, LC, SC, ST, MT-RJ, etc., will all be a thing of the past.

Infiberone, as a cabling solution provider, is now going to be ahead of the game with MPO/MTP cables that are designed for the reliable and quick operations in Data Centers. The obvious benefits of these cables are less space requirements and improved scalability, providing significant space and cost savings. The MPO/MTP cables are generally used for 40GbE and 100GbE network environment, and play a significant part of structured cabling. We offer a wide range of MPO/MTP cable assemblies including Trunk Cables, Harness Cables, patch-cords, loopback modules, Hydra cables and Cassettes (or Patch Panels). All the assemblies are fully compliant with IEC Standards 61754-7 and TIA 604-5, and Telcordia GR-1435-CORE., we also provide customized design such as optional fiber counts, cable types and lengths etc.


Typical Application Scenario—Data Center SAN


1,Patch Cords
MTP/MPO patch cables are commonly used when 40G or 100G active transceivers (e.g., QSFP+ and CFP transceivers) are employed with MTP/MPO interface. The ends of MTP/MPO patch cables are terminated with the customer's choice of 12-fiber or 24-fiber MPO connectors. Available in a male-to-male version (left with guide pins) and a female-to-female version (without pins), these cables are used in various applications such as all-optical networking and devices like 40G/100G modules.

2,Truck Cable
MPO/MTP trunk cables serve as a permanent link connecting MPO/MTP modules to each other. The trunk cables are available with 12, 24, 48 and 72 fibers. A 72-fiber trunk cable can be terminated with 6 MPO/MTP connectors and the connectors are manufactured specifically for multi-fiber loose tube or ribbon cable.
MPO/MTP trunk cables are used to interconnect cassettes, panels or ruggedized MPO fan-outs, spanning MDA, HDA and EDA areas, and to facilitate rapid deployment of high density backbone cabling in data centers and other high fiber environments reducing network installation or reconfiguration. They offer the flexibility in case any decision is made to change the connector style in the patch panels, new cassettes can be installed with the new connector style on the cross-connect side of the patch panel without having to change the connector on the cable trunk.

Infiberone provides high density MPO/MTP trunk cables including standard trunk cables and hybrid trunk cables, with up to 288 fibers in a single cable. The MPO/MTP trunk cables use a compact and rugged micro cable structure, according to different colors divided into Single-Mode (SM), Multi-Mode (MM) and 10G MM. The fiber ranges from 12 to 144, MTP polarity options are TIA way is Style A (up), Style B (down) and Style C (up/up). The cable length can be up to 999 feet, and breakout length from 12 to 99 inches.

3,Harness Cable
MPO/MTP harness cables provide a transition from multi-fiber cables to individual fibers or duplex connectors. These cables are offered for various applications for all networking and device needs like 100G modules including CFP, CFP2 and CFP4 series. It provides a reliable, cost-effective cabling system for migrating from legacy 10G to higher speed 40G/100G Ethernet ect. e.g. our 12F MPO to 4 duplex LC can be used to connect four 10G SFP+ with one 40G QSFP+, and 24MPO to 3-8f MPO is used to connect three 40G QSFP+ with one 120G CXP.

4 Casstte Modules and Hydra Cables
Modular system allows for rapid deployment of high density data center infrastructure as well as improved troubleshooting and reconfiguration during moves, adds and changes. The MPO/MTP cassettes are such modules which enable users to take the fibers brought by a trunk cable and distribute them to a duplex cable. As already assembled units, the MPO cassette modules are fitted with 12 or 24 fibers and have LC, SC or E2000 adapters on the front side and MPO/MTP at the rear, this is to say, inside a standard LGX cassette module, there is a hydra cable.


40G/100G Application

Based on Parallel Opyical Interface Technology, a female MPO/MTP patchcord must be used between two 40G or 100G transceiver. These cables are offered for various applications for all networking and device needs like 100G modules including CFP, CFP2 and CFP4 series. It provides a reliable, cost-effective cabling system for migrating from legacy 10G to higher speed 40G/100G Ethernet ect. e.g. our 12F MPO to 4 duplex LC can be used to connect four 10G SFP+ with one 40G QSFP+, and 24MPO to 3-8f MPO is used to connect three 40G QSFP+ with one 120G CXP.



Infiberone’s MPO/MTP Y cables are particularly designed to connect two high-speed transceivers, which provides a reliable, cost-effective cabling system for migrating from legacy 10G to higher speed 40G/100G Ethernet ect. e.g. our 12F MPO to 4 duplex LC can be used to connect four 10G SFP+ with one 40G QSFP+, and 24MPO to 3-8f MPO is used to connect three 40G QSFP+ with one 120G CXP. Infiberone can provide customized MPO/MTP solutions for specific application.

More to known: http://www.infiberone.com/Solutions.html